Skip to content
  • Philippe Gerum's avatar
    cobalt/clock: drop timer calibration · 9466bfd1
    Philippe Gerum authored and Jan Kiszka's avatar Jan Kiszka committed
    
    
    The calibrated timer setup time is currently accounted for in the
    timer gravity triplet (.user, also used as default .irq latency),
    exclusively. This forces in a dynamically calculated parameter with no
    way to override it. Meanwhile, this value would be already included in
    every gravity value which autotune may determine, so this setting is
    pretty much redundant.
    
    Drop nktimerlat and the requirement for the machine section to provide
    a timer calibration handler, we don't need these.
    
    Signed-off-by: default avatarPhilippe Gerum <rpm@xenomai.org>
    Signed-off-by: default avatarJan Kiszka <jan.kiszka@siemens.com>