According to S26KL512S datasheet [1] and S29GL01GS datasheet [2], the procedure to read out PPB lock bits is to send the PPB Entry, PPB Read, Reset/ASO Exit. Currently, the code does send incorrect PPB Entry, PPB Read and Reset/ASO Exit is completely missing. The PPB Entry sent is implemented by sending flash_unlock_seq() and flash_write_cmd(..., FLASH_CMD_READ_ID). This translates to sequence 0x555:0xaa, 0x2aa:0x55, 0x555:0x90=FLASH_CMD_READ_ID. However, both [1] and [2] specify the last byte of PPB Entry as 0xc0=AMD_CMD_SET_PPB_ENTRY instead of 0x90=FLASH_CMD_READ_ID, that is 0x555:0xaa, 0x2aa:0x55, 0x555:0xc0=AMD_CMD_SET_PPB_ENTRY. Since this does make sense, this patch fixes it and thus also aligns the code in flash_get_size() with flash_real_protect(). The PPB Read returns 00h in case of Protected state and 01h in case of Unprotected state, according to [1] Note 83 and [2] Note 17, so invert the result. Moreover, align the arguments with similar code in flash_real_protect(). Finally, Reset/ASO Exit command should be executed to exit the PPB mode, so add the missing reset. [1] https://www.cypress.com/file/213346/download Document Number: 001-99198 Rev. *M Table 40. Command Definitions, Nonvolatile Sector Protection Command Set Definitions [2] https://www.cypress.com/file/177976/download Document Number: 001-98285 Rev. *R Table 7.1 Command Definitions, Nonvolatile Sector Protection Command Set Definitions Fixes: 03deff43 ("cfi_flash: Read PPB sector protection from device for AMD/Spansion chips") Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Stefan Roese <sr@denx.de> Reviewed-by: Stefan Roese <sr@denx.de>
94657482